This article originates from Sunrise Big data and is compiled by ChipSourceTek. The information has not been officially confirmed and is only for exchange and learning.
6. Allegro
| 
             
  | 
            
             PCAD EDA For   Windows  | 
            
             CADENCE Allegro  | 
            
             PADS PowerPCB  | 
            
             
  | 
        
| 
             Hardware   requirements  | 
            
             586 more than IBM PC   compatible, minimum 128MB RAM  | 
            
             586 more than IBM   PC compatible, minimum 64MB RAM  | 
            
             586 more than IBM   PC compatible, minimum 128MB RAM  | 
            
             586 more than IBM   PC compatible, minimum 64MB RAM  | 
        
| 
             work environment  | 
            
             
  | 
            
             Win 95/3.1/NT  | 
            
             WinNT/2K Unix  | 
            
             windows  | 
        
| 
             Ease of operation   of interface and instructions  | 
            
             Very friendly,   extremely simple  | 
            
             simple and easy  | 
            
             Cumbersome  | 
            
             simple and easy  | 
        
| 
             Design   Architecture  | 
            
             simulation 32bit  | 
            
             real mode 32 bit   AP  | 
            
             32bit  | 
            
             32bit  | 
        
| 
             Schematic  | 
            
             have  | 
            
             have  | 
            
             have(optional Orcad)  | 
            
             have(optional )  | 
        
| 
             Removable Error   ID  | 
            
             Yes  | 
            
             Yes  | 
            
             Yes  | 
            
             Yes  | 
        
| 
             Analog Digital   Signal Simulation  | 
            
             Yes  | 
            
             Yes  | 
            
             Outsourcing  | 
            
             Outsourcing  | 
        
| 
             density analysis  | 
            
             have  | 
            
             No have  | 
            
             No have  | 
            
             No have  | 
        
| 
             Preview of   components  | 
            
             Yes  | 
            
             No  | 
            
             Yes  | 
            
             Yes  | 
        
| 
             Global editing   function (Global)  | 
            
             Yes  | 
            
             No  | 
            
             No  | 
            
             No  | 
        
| 
             Maximum Board   Size  | 
            
             80“x80”  | 
            
             60“x60”  | 
            
             Based on the   resolution of the cell, if it is 2, it is millions of square inches  | 
            
             50“x50”  | 
        
| 
             Layout level   settings  | 
            
             32 storey  | 
            
             infinite layer  | 
            
             infinite layer  | 
            
             60 storey  | 
        
| 
             signal layer  | 
            
             
  | 
            
             32 storey  | 
            
             108 electrical   layer  | 
            
             16 storey  | 
        
| 
             Circuit diagram   VS PCB  | 
            
             Yes  | 
            
             Yes  | 
            
             Yes  | 
            
             Yes(choose)  | 
        
| 
             On Line DRC  | 
            
             
  | 
            
             Yes  | 
            
             Yes  | 
            
             Yes  | 
        
| 
             DXFin&Laye limitations  | 
            
             Restricted Inclusion  | 
            
             Unlimited   Inclusion  | 
            
             unlimited  | 
            
             Restricted   purchase  | 
        
| 
             Pro-Einterface  | 
            
             Outsourcing  | 
            
             Yes  | 
            
             Yes  | 
            
             choose  | 
        
| 
             Polygon Arc  | 
            
             Yes  | 
            
             Yes  | 
            
             Yes  | 
            
             Yes  | 
        
| 
             Polygon Void  | 
            
             Yes  | 
            
             Yes  | 
            
             Yes  | 
            
             Yes  | 
        
| 
             Component search   function  | 
            
             Strong, query range   can be across the entire hard drive or even the entire network of the user‘s   company  | 
            
             Yes (not strong)  | 
            
             No (relatively weak)  | 
            
             Yes (but not strong)  | 
        
| 
             Design of Plate and   Frame  | 
            
             The software provides   10 types of boards that can be manually drawn and loaded into DXF files  | 
            
             Can only be manually   drawn and loaded into DXF files  | 
            
             Can only be manually   drawn and loaded into DXF files  | 
            
             Can only be manually   drawn and loaded into DXF files  | 
        
| 
             ICT automatic   testing data for test machine  | 
            
             
  | 
            
             Yes  | 
            
             Option (performance)  | 
            
             option  | 
        
| 
             Pre Autoroute  | 
            
             
  | 
            
             Yes  | 
            
             Yes  | 
            
             choose  | 
        
| 
             Including CAM   software  | 
            
             
  | 
            
             Yes  | 
            
             Yes  | 
            
             No  | 
        
| 
             Signal integrity  | 
            
             
  | 
            
             Yes  | 
            
             option  | 
            
             choose  | 
        
| 
             Node lock Price  | 
            
             NT 310,000  | 
            
             NT350,000  | 
            
             Us$16000  | 
            
             NT650,000  | 
        
| 
             Network Price  | 
            
             No  | 
            
             NT437,000  | 
            
                | 
            
             NT810,000  | 
        
| 
             project  | 
            
             
  | 
            
             P-CAD 2001  | 
            
             CADENCE Allegro  | 
            
             Power pcb 4.0  | 
        
| 
             Power Logic  | 
            
             have  | 
            
             have  | 
            
             have  | 
            
             have﹝choose﹞  | 
        
| 
             Dynamic Route   Editor  | 
            
             have  | 
            
             have  | 
            
             have  | 
            
             have  | 
        
| 
             Auto Dimension  | 
            
             have  | 
            
             have  | 
            
             have  | 
            
             have  | 
        
| 
             EMC Line sim  | 
            
             have﹝choose﹞  | 
            
             have  | 
            
             have﹝choose﹞  | 
            
             have﹝choose﹞  | 
        
| 
             EMC Board sim  | 
            
             have﹝choose﹞  | 
            
             have  | 
            
             have﹝choose﹞  | 
            
             have﹝choose﹞  | 
        
| 
             Continuity of old   data  | 
            
             Only Win version   compatible  | 
            
             have  | 
            
             Unix only, Win   version compatible  | 
            
             Only Win version   compatible  | 
        
| 
             Layer Settings  | 
            
             32 layer electrical   layer, 16 layer plane layer, 16 layer mechanism marking layer, and other   internal text layer and steel plate layer  | 
            
             999 floors, 990   floors Electrical layer  | 
            
             108 electrical   layers, unlimited non electrical layers  | 
            
             250 floors in   total, 64 electrical floors  | 
        
| 
             DXF LINK  | 
            
             
  | 
            
             have  | 
            
             have  | 
            
             have﹝choose﹞  | 
        
| 
             Pro-E LINK  | 
            
             
  | 
            
             have  | 
            
             have  | 
            
             have﹝choose﹞  | 
        
| 
             Edit  | 
            
             have  | 
            
             have  | 
            
             have  | 
            
             have﹝choose﹞  | 
        
| 
             3D PCB Viewer  | 
            
             have  | 
            
             not have  | 
            
             not have  | 
            
             have﹝choose﹞  | 
        
| 
             UnDo/ReDo  | 
            
             Strong, even if the   file has been saved, it is still available, and it is convenient to edit the   undo/redo times  | 
            
             Yes   (customization is quite cumbersome and not very powerful)  | 
            
             not have  | 
            
             have(But not strong)  | 
        
| 
             Design accuracy  | 
            
             0.001Mil  | 
            
             0.1Mil  | 
            
             0.0001Mil  | 
            
             0.01Mil  | 
        
| 
             Name of custom   layer  | 
            
             Yes  | 
            
             Yes  | 
            
             Yes  | 
            
             Yes  | 
        
| 
             Automatic   avoidance of obstacles  | 
            
             Yes  | 
            
             Yes  | 
            
             Yes  | 
            
             Yes  | 
        
| 
             Automatic wiring   support for pre wiring  | 
            
             strong  | 
            
             have  | 
            
             have  | 
            
             no have  | 
        
| 
             Design rule   support for automatic wiring  | 
            
             strong  | 
            
             have  | 
            
             have  | 
            
             have  | 
        
| 
             Design Browser  | 
            
             have(And strong)  | 
            
             no have  | 
            
             no have  | 
            
             no have  | 
        
| 
             Digital   Simulation  | 
            
             Yes  | 
            
             Yes  | 
            
             Optional  | 
            
             Optional  | 
        
| 
             Custom level  | 
            
             Yes  | 
            
             Yes  | 
            
             Yes  | 
            
             Yes  | 
        
| 
             Cancellation of   rules  | 
            
             Yes  | 
            
             Yes  | 
            
             Yes  | 
            
             Yes  | 
        
| 
             The shape of   tears  | 
            
             Line/Arc  | 
            
             have  | 
            
             have  | 
            
             have  | 
        
| 
             Teardrop removal  | 
            
             Yes  | 
            
             Yes  | 
            
             Yes  | 
            
             Yes  | 
        
| 
                 Disclaimer: This article is transferred from other platforms and does not represent the views and positions of this site. If there is any infringement or objection, please contact us to delete it. thank you!  | 
        
		